{"id":1370,"date":"2011-11-30T02:43:54","date_gmt":"2011-11-30T07:43:54","guid":{"rendered":"http:\/\/instrumentacionycontrol.net\/?p=1370"},"modified":"2021-02-05T10:53:40","modified_gmt":"2021-02-05T15:53:40","slug":"measurement-of-level-by-radioactive-type","status":"publish","type":"post","link":"https:\/\/instrumentacionycontrol.net\/en\/medicion-de-nivel-por-tipo-radioactivo\/","title":{"rendered":"RADIOACTIVE LEVEL MEASUREMENT BY TYPE"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><strong>LEVEL MEASUREMENT BY RADIOACTIVE EQUIPMENT<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">There are processes in which it is no longer possible to perform level measurements with the aforementioned elements when they are at high temperatures, high pressures, in corrosive, toxic, or highly explosive environments, etc. In short, we cannot insert a level measurement instrument.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The last extreme alternative is nuclear measurement equipment. This equipment uses an ionizing radiation source, usually Cesium-137 or Cobalt-60, although Cesium-137 is the most common. This radioactive element has a half-life of approximately 15 years. The unit of measurement for the radiation source is Ci, or Curie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The operation of this equipment is defined by an ionizing radiation source and a detector. In the 100% case, the source has a gate that blocks the radiation beam from exiting, for the protection of personnel. This gate must be opened by qualified personnel authorized by the regulatory body in the corresponding country. The detector can be an inert gas chamber that is excited by the radiation and generates a millivoltage, or a fiber optic tube that concentrates the radiation pulses, which are then amplified and counted by specialized electronics that interpret this as a value.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Most of the time, nuclear equipment is used as Level Contacts or Switches, meaning that the presence of the material to be detected only sees a Point, it can be a High Level or a Low Level, ON-OFF, 0-1, etc.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In the case of needing to detect a level variation, analog values, or continuous measurement, the configuration remains the same, but the detector and its position change, since I must allow the radiation beam projection to have a larger projection area or control surface, and the detector is also larger so that it can cover the entire area I need to measure.<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><br><img loading=\"lazy\" decoding=\"async\" width=\"467\" height=\"189\" src=\"http:\/\/instrumentacionycontrol.net\/wp-content\/uploads\/2017\/10\/radio_01.jpg\" alt=\"\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br>The different ways a source with a detector can be arranged are shown here.<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><br><img loading=\"lazy\" decoding=\"async\" width=\"515\" height=\"309\" src=\"http:\/\/instrumentacionycontrol.net\/wp-content\/uploads\/2017\/10\/radio_02.jpg\" alt=\"\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br>This represents the chamber in which there is an inert gas that, when bombarded by radioactive particles, generates a millivoltage that is proportional to the amount of radiation that arrives. This means that the sensor where it will be installed must be calibrated, but without the presence of the medium to be measured, which will be a 100% of radiation; the missing radiation will be absorbed by the medium to be measured.<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><br><img loading=\"lazy\" decoding=\"async\" width=\"467\" height=\"436\" src=\"http:\/\/instrumentacionycontrol.net\/wp-content\/uploads\/2017\/10\/radio_03.jpg\" alt=\"\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br>This equipment corresponds to a scintillation-type detector, where the radiation creates light traces that are read by the amplification electronics and interpreted as the amount of radiation.<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><br><img loading=\"lazy\" decoding=\"async\" width=\"528\" height=\"704\" src=\"http:\/\/instrumentacionycontrol.net\/wp-content\/uploads\/2017\/10\/feeder_02.jpg\" alt=\"\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br>Nuclear Source for Low Low Level (LSLL) Detection of Copper Ore.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Thank you very much, any questions or queries can be sent to the following email:<br><a href=\"mailto: hcarrasco@instrumentacionycontrol.net\">hcarrasco@instrumentacionycontrol.net<\/a><br>Twitter: @instrumentacion<\/p>\n\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Help us grow <\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Finally, if you are determined to learn Industrial Automation and advance your professional career, you may be interested in our Premium courses:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2013 Click to see all our courses at <a rel=\"noreferrer noopener\" href=\"https:\/\/myautomationclass.com\/?utm_source=iycnet&amp;utm_medium=post&amp;utm_campaign=footer_link_post\" target=\"_blank\">MyAutomationClass.com <\/a><br>- Course: <a rel=\"noreferrer noopener\" href=\"https:\/\/myautomationclass.com\/p\/aprende-plcs-desde-cero-con-rslogix500-basico-avanzado?utm_source=iycnet&amp;utm_medium=post&amp;utm_campaign=footer_link_post\" target=\"_blank\">\u00ab&quot;Become a PLC expert in 60 days, from basic to pro&quot;\u00bb <\/a><br>- Course: <a rel=\"noreferrer noopener\" href=\"https:\/\/myautomationclass.com\/p\/aprende-controladores-pid-de-manera-practica?utm_source=iycnet&amp;utm_medium=post&amp;utm_campaign=footer_link_post\" target=\"_blank\">\u00ab&quot;PID Controllers Master Class \u2013 100% practical&quot;\u00bb <\/a><br>- Course:<a rel=\"noreferrer noopener\" href=\"https:\/\/myautomationclass.com\/p\/desarrollo-de-proyectos-scadahmi-con-wonderware-intouch?utm_source=iycnet&amp;utm_medium=post&amp;utm_campaign=footer_link_post\" target=\"_blank\"> \u00ab&quot;How to create SCADA\/HMI projects from scratch with InTouch&quot;\u00bb <\/a><br>- Course:<a rel=\"noreferrer noopener\" href=\"https:\/\/myautomationclass.com\/p\/pid-tuning-ultimate-sintonizacion?utm_source=iycnet&amp;utm_medium=post&amp;utm_campaign=footer_link_post\" target=\"_blank\"> \u00ab&quot;PID Tuning Ultimate: The Definitive Course for Tuning&quot;\u00bb <\/a><br>- Course:<a rel=\"noreferrer noopener\" href=\"https:\/\/myautomationclass.com\/p\/modelamiento-practico-de-procesos-10-pasos-impresindibles-para-ser-un-experto?utm_source=iycnet&amp;utm_medium=post&amp;utm_campaign=footer_link_post\" target=\"_blank\"> \u00ab&quot;Practical Process Modeling: Definitive Steps to Becoming an Expert&quot;\u00bb <\/a><br>- Program:<a rel=\"noreferrer noopener\" href=\"https:\/\/myautomationclass.com\/p\/the-ultimate-process-control-training-se-un-maestro-control-pid?utm_source=iycnet&amp;utm_medium=post&amp;utm_campaign=footer_link_post\" target=\"_blank\"> \u00ab&quot;The Ultimate Process Control Formula&quot; (All-inclusive: PID Control, Tuning, and Modeling)<\/a> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">- Course: <a href=\"https:\/\/myautomationclass.com\/p\/aprende-instrumentacion-industrial-facil\" target=\"_blank\" rel=\"noreferrer noopener\">How to Learn Industrial Instrumentation, Easily (Complete)<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If you have any questions, contact us via <a rel=\"noreferrer noopener\" href=\"http:\/\/m.me\/instrumentacionycontrol.net\" target=\"_blank\">Facebook Messenger<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Until next time. COMMENT AND SHARE! I&#039;ll be happy to answer your questions.<\/p>\n<\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>MEDICI\u00d3N&nbsp;DE NIVEL POR EQUIPOS RADIOACTIVOS Existen Procesos en lo cuales, ya no es imposible poder realizar mediciones de nivel con los elementos antes mencionado, cuando estos se encuentran a altas temperatura, alta presi\u00f3n, procesos corrosivos, procesos t\u00f3xicos, altamente explosivos, etc. En definitiva, no podemos insertar un instrumento para la medici\u00f3n de nivel. La alternativa extrema [&hellip;]<\/p>\n","protected":false},"author":2356,"featured_media":12626,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"footnotes":""},"categories":[88],"tags":[305,166,704,377,703],"class_list":["post-1370","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-curso-medicion-de-nivel-practico","tag-medicion","tag-nivel","tag-radioactivos","tag-sensores","tag-tipo","post-wrapper","thrv_wrapper"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>MEDICI\u00d3N DE NIVEL POR TIPO RADIOACTIVO<\/title>\n<meta name=\"description\" content=\"Existen Procesos en lo cuales, ya no es imposible poder realizar mediciones de nivel con los elementos antes mencionado, cuando estos se encuentran a altas temperatura, alta presi\u00f3n, procesos corrosivos, procesos t\u00f3xicos, altamente explosivos, etc. En definitiva, no podemos insertar un instrumento para la medici\u00f3n de nivel.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/instrumentacionycontrol.net\/en\/measurement-of-level-by-radioactive-type\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"MEDICI\u00d3N DE NIVEL POR TIPO RADIOACTIVO\" \/>\n<meta property=\"og:description\" content=\"Existen Procesos en lo cuales, ya no es imposible poder realizar mediciones de nivel con los elementos antes mencionado, cuando estos se encuentran a altas temperatura, alta presi\u00f3n, procesos corrosivos, procesos t\u00f3xicos, altamente explosivos, etc. En definitiva, no podemos insertar un instrumento para la medici\u00f3n de nivel.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/instrumentacionycontrol.net\/en\/measurement-of-level-by-radioactive-type\/\" \/>\n<meta property=\"og:site_name\" content=\"Instrumentacion y Automatizacion Industrial\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/instrumentacionycontrol.net\" \/>\n<meta property=\"article:published_time\" content=\"2011-11-30T07:43:54+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-02-05T15:53:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/instrumentacionycontrol.net\/wp-content\/uploads\/2011\/11\/MEDICI\u00d3N_NIVEL_TIPO_RADIOACTIVO.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"640\" \/>\n\t<meta property=\"og:image:height\" content=\"480\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Hector Carrasco\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@iycnet\" \/>\n<meta name=\"twitter:site\" content=\"@iycnet\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Hector Carrasco\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/medicion-de-nivel-por-tipo-radioactivo\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/medicion-de-nivel-por-tipo-radioactivo\\\/\"},\"author\":{\"name\":\"Hector Carrasco\",\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/#\\\/schema\\\/person\\\/5be10c1f066c0565b938a2f535219cdd\"},\"headline\":\"MEDICI\u00d3N DE NIVEL POR TIPO RADIOACTIVO\",\"datePublished\":\"2011-11-30T07:43:54+00:00\",\"dateModified\":\"2021-02-05T15:53:40+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/medicion-de-nivel-por-tipo-radioactivo\\\/\"},\"wordCount\":535,\"commentCount\":2,\"publisher\":{\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/medicion-de-nivel-por-tipo-radioactivo\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/wp-content\\\/uploads\\\/2011\\\/11\\\/MEDICI\u00d3N_NIVEL_TIPO_RADIOACTIVO.jpg\",\"keywords\":[\"medicion\",\"nivel\",\"RADIOACTIVOS\",\"sensores\",\"TIPO\"],\"articleSection\":[\"Curso Medici\u00f3n de Nivel Pr\u00e1ctico\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/instrumentacionycontrol.net\\\/medicion-de-nivel-por-tipo-radioactivo\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/medicion-de-nivel-por-tipo-radioactivo\\\/\",\"url\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/medicion-de-nivel-por-tipo-radioactivo\\\/\",\"name\":\"MEDICI\u00d3N DE NIVEL POR TIPO RADIOACTIVO\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/medicion-de-nivel-por-tipo-radioactivo\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/medicion-de-nivel-por-tipo-radioactivo\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/wp-content\\\/uploads\\\/2011\\\/11\\\/MEDICI\u00d3N_NIVEL_TIPO_RADIOACTIVO.jpg\",\"datePublished\":\"2011-11-30T07:43:54+00:00\",\"dateModified\":\"2021-02-05T15:53:40+00:00\",\"description\":\"Existen Procesos en lo cuales, ya no es imposible poder realizar mediciones de nivel con los elementos antes mencionado, cuando estos se encuentran a altas temperatura, alta presi\u00f3n, procesos corrosivos, procesos t\u00f3xicos, altamente explosivos, etc. En definitiva, no podemos insertar un instrumento para la medici\u00f3n de nivel.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/medicion-de-nivel-por-tipo-radioactivo\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/instrumentacionycontrol.net\\\/medicion-de-nivel-por-tipo-radioactivo\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/medicion-de-nivel-por-tipo-radioactivo\\\/#primaryimage\",\"url\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/wp-content\\\/uploads\\\/2011\\\/11\\\/MEDICI\u00d3N_NIVEL_TIPO_RADIOACTIVO.jpg\",\"contentUrl\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/wp-content\\\/uploads\\\/2011\\\/11\\\/MEDICI\u00d3N_NIVEL_TIPO_RADIOACTIVO.jpg\",\"width\":640,\"height\":480,\"caption\":\"MEDICI\u00d3N DE NIVEL POR TIPO RADIOACTIVO\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/medicion-de-nivel-por-tipo-radioactivo\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"MEDICI\u00d3N DE NIVEL POR TIPO RADIOACTIVO\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/#website\",\"url\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/\",\"name\":\"Instrumentacion y Automatizacion Industrial\",\"description\":\"Tu sitio de Automatizacion e Instrumentacion Industrial\",\"publisher\":{\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/#organization\",\"name\":\"InstrumentacionyControl.NET\",\"url\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/wp-content\\\/uploads\\\/2020\\\/04\\\/Logo-IyCnet1.png\",\"contentUrl\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/wp-content\\\/uploads\\\/2020\\\/04\\\/Logo-IyCnet1.png\",\"width\":299,\"height\":75,\"caption\":\"InstrumentacionyControl.NET\"},\"image\":{\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/instrumentacionycontrol.net\",\"https:\\\/\\\/x.com\\\/iycnet\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/josevillajulca\\\/\",\"https:\\\/\\\/youtube.com\\\/user\\\/iycnet\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/#\\\/schema\\\/person\\\/5be10c1f066c0565b938a2f535219cdd\",\"name\":\"Hector Carrasco\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8844b0b90245ca4a7df06aefb87b493037740da050e6999ca96869b5328def32?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8844b0b90245ca4a7df06aefb87b493037740da050e6999ca96869b5328def32?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8844b0b90245ca4a7df06aefb87b493037740da050e6999ca96869b5328def32?s=96&d=identicon&r=g\",\"caption\":\"Hector Carrasco\"},\"url\":\"https:\\\/\\\/instrumentacionycontrol.net\\\/en\\\/author\\\/hcarrasco\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"RADIOACTIVE LEVEL MEASUREMENT BY TYPE","description":"There are processes in which it is no longer possible to perform level measurements with the aforementioned elements when they are at high temperatures, high pressures, in corrosive, toxic, or highly explosive environments, etc. In short, we cannot insert a level measurement instrument.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/instrumentacionycontrol.net\/en\/measurement-of-level-by-radioactive-type\/","og_locale":"en_US","og_type":"article","og_title":"MEDICI\u00d3N DE NIVEL POR TIPO RADIOACTIVO","og_description":"Existen Procesos en lo cuales, ya no es imposible poder realizar mediciones de nivel con los elementos antes mencionado, cuando estos se encuentran a altas temperatura, alta presi\u00f3n, procesos corrosivos, procesos t\u00f3xicos, altamente explosivos, etc. En definitiva, no podemos insertar un instrumento para la medici\u00f3n de nivel.","og_url":"https:\/\/instrumentacionycontrol.net\/en\/measurement-of-level-by-radioactive-type\/","og_site_name":"Instrumentacion y Automatizacion Industrial","article_publisher":"https:\/\/www.facebook.com\/instrumentacionycontrol.net","article_published_time":"2011-11-30T07:43:54+00:00","article_modified_time":"2021-02-05T15:53:40+00:00","og_image":[{"width":640,"height":480,"url":"https:\/\/instrumentacionycontrol.net\/wp-content\/uploads\/2011\/11\/MEDICI\u00d3N_NIVEL_TIPO_RADIOACTIVO.jpg","type":"image\/jpeg"}],"author":"Hector Carrasco","twitter_card":"summary_large_image","twitter_creator":"@iycnet","twitter_site":"@iycnet","twitter_misc":{"Written by":"Hector Carrasco","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/instrumentacionycontrol.net\/medicion-de-nivel-por-tipo-radioactivo\/#article","isPartOf":{"@id":"https:\/\/instrumentacionycontrol.net\/medicion-de-nivel-por-tipo-radioactivo\/"},"author":{"name":"Hector Carrasco","@id":"https:\/\/instrumentacionycontrol.net\/#\/schema\/person\/5be10c1f066c0565b938a2f535219cdd"},"headline":"MEDICI\u00d3N DE NIVEL POR TIPO RADIOACTIVO","datePublished":"2011-11-30T07:43:54+00:00","dateModified":"2021-02-05T15:53:40+00:00","mainEntityOfPage":{"@id":"https:\/\/instrumentacionycontrol.net\/medicion-de-nivel-por-tipo-radioactivo\/"},"wordCount":535,"commentCount":2,"publisher":{"@id":"https:\/\/instrumentacionycontrol.net\/#organization"},"image":{"@id":"https:\/\/instrumentacionycontrol.net\/medicion-de-nivel-por-tipo-radioactivo\/#primaryimage"},"thumbnailUrl":"https:\/\/instrumentacionycontrol.net\/wp-content\/uploads\/2011\/11\/MEDICI\u00d3N_NIVEL_TIPO_RADIOACTIVO.jpg","keywords":["medicion","nivel","RADIOACTIVOS","sensores","TIPO"],"articleSection":["Curso Medici\u00f3n de Nivel Pr\u00e1ctico"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/instrumentacionycontrol.net\/medicion-de-nivel-por-tipo-radioactivo\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/instrumentacionycontrol.net\/medicion-de-nivel-por-tipo-radioactivo\/","url":"https:\/\/instrumentacionycontrol.net\/medicion-de-nivel-por-tipo-radioactivo\/","name":"RADIOACTIVE LEVEL MEASUREMENT BY TYPE","isPartOf":{"@id":"https:\/\/instrumentacionycontrol.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/instrumentacionycontrol.net\/medicion-de-nivel-por-tipo-radioactivo\/#primaryimage"},"image":{"@id":"https:\/\/instrumentacionycontrol.net\/medicion-de-nivel-por-tipo-radioactivo\/#primaryimage"},"thumbnailUrl":"https:\/\/instrumentacionycontrol.net\/wp-content\/uploads\/2011\/11\/MEDICI\u00d3N_NIVEL_TIPO_RADIOACTIVO.jpg","datePublished":"2011-11-30T07:43:54+00:00","dateModified":"2021-02-05T15:53:40+00:00","description":"There are processes in which it is no longer possible to perform level measurements with the aforementioned elements when they are at high temperatures, high pressures, in corrosive, toxic, or highly explosive environments, etc. In short, we cannot insert a level measurement instrument.","breadcrumb":{"@id":"https:\/\/instrumentacionycontrol.net\/medicion-de-nivel-por-tipo-radioactivo\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/instrumentacionycontrol.net\/medicion-de-nivel-por-tipo-radioactivo\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/instrumentacionycontrol.net\/medicion-de-nivel-por-tipo-radioactivo\/#primaryimage","url":"https:\/\/instrumentacionycontrol.net\/wp-content\/uploads\/2011\/11\/MEDICI\u00d3N_NIVEL_TIPO_RADIOACTIVO.jpg","contentUrl":"https:\/\/instrumentacionycontrol.net\/wp-content\/uploads\/2011\/11\/MEDICI\u00d3N_NIVEL_TIPO_RADIOACTIVO.jpg","width":640,"height":480,"caption":"MEDICI\u00d3N DE NIVEL POR TIPO RADIOACTIVO"},{"@type":"BreadcrumbList","@id":"https:\/\/instrumentacionycontrol.net\/medicion-de-nivel-por-tipo-radioactivo\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/instrumentacionycontrol.net\/"},{"@type":"ListItem","position":2,"name":"MEDICI\u00d3N DE NIVEL POR TIPO RADIOACTIVO"}]},{"@type":"WebSite","@id":"https:\/\/instrumentacionycontrol.net\/#website","url":"https:\/\/instrumentacionycontrol.net\/","name":"Industrial Instrumentation and Automation","description":"Your site for Industrial Automation and Instrumentation","publisher":{"@id":"https:\/\/instrumentacionycontrol.net\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/instrumentacionycontrol.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/instrumentacionycontrol.net\/#organization","name":"InstrumentationandControl.NET","url":"https:\/\/instrumentacionycontrol.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/instrumentacionycontrol.net\/#\/schema\/logo\/image\/","url":"https:\/\/instrumentacionycontrol.net\/wp-content\/uploads\/2020\/04\/Logo-IyCnet1.png","contentUrl":"https:\/\/instrumentacionycontrol.net\/wp-content\/uploads\/2020\/04\/Logo-IyCnet1.png","width":299,"height":75,"caption":"InstrumentacionyControl.NET"},"image":{"@id":"https:\/\/instrumentacionycontrol.net\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/instrumentacionycontrol.net","https:\/\/x.com\/iycnet","https:\/\/www.linkedin.com\/in\/josevillajulca\/","https:\/\/youtube.com\/user\/iycnet"]},{"@type":"Person","@id":"https:\/\/instrumentacionycontrol.net\/#\/schema\/person\/5be10c1f066c0565b938a2f535219cdd","name":"Hector Carrasco","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/8844b0b90245ca4a7df06aefb87b493037740da050e6999ca96869b5328def32?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8844b0b90245ca4a7df06aefb87b493037740da050e6999ca96869b5328def32?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8844b0b90245ca4a7df06aefb87b493037740da050e6999ca96869b5328def32?s=96&d=identicon&r=g","caption":"Hector Carrasco"},"url":"https:\/\/instrumentacionycontrol.net\/en\/author\/hcarrasco\/"}]}},"_links":{"self":[{"href":"https:\/\/instrumentacionycontrol.net\/en\/wp-json\/wp\/v2\/posts\/1370","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/instrumentacionycontrol.net\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/instrumentacionycontrol.net\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/instrumentacionycontrol.net\/en\/wp-json\/wp\/v2\/users\/2356"}],"replies":[{"embeddable":true,"href":"https:\/\/instrumentacionycontrol.net\/en\/wp-json\/wp\/v2\/comments?post=1370"}],"version-history":[{"count":0,"href":"https:\/\/instrumentacionycontrol.net\/en\/wp-json\/wp\/v2\/posts\/1370\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/instrumentacionycontrol.net\/en\/wp-json\/wp\/v2\/media\/12626"}],"wp:attachment":[{"href":"https:\/\/instrumentacionycontrol.net\/en\/wp-json\/wp\/v2\/media?parent=1370"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/instrumentacionycontrol.net\/en\/wp-json\/wp\/v2\/categories?post=1370"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/instrumentacionycontrol.net\/en\/wp-json\/wp\/v2\/tags?post=1370"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}